FIXA2 Spot Welding Cap Tip Sensor
by Kyokutoh
- Able to avoid poor weld through regular detecting operation of tip face.
- The sensor reckon good tip face by proper reflecting light amount of cap tip.
- Please set the gun pressure up to 200kgf during detecting.
- Tip face is identified either OK or NG by the signal of Tip manager.
※ Please contact us for the inquiry using special tip shapes.
Specification
Power voltage [DC] | 12-24 | |||||||
Power Consumption | Under 3W | |||||||
Control output | Open Collector | Under DC24V | ||||||
OUTPUT Max | 100mA | |||||||
Air pressure (MPa) | 0.4-0.6 | |||||||
Environmental | Operating ambient luminace | Incandescent lamp : 20.000lx Sunlight : 30.000lx | ||||||
Resistance | Operating ambient temperature | -0℃~+40℃(no freezing) | ||||||
Operating ambient Humidity | 35~75%RH(no condensation) |